ElvaX

MODEL: ELVAX
Description

XRF analyzer "ElvaX"  is a desktop energy-dispersive X-ray fluorescence EDXRF analyzer|spectrometer  which does not require liquid nitrogen cooling for storage and use. ElvaX EDXRF analyzer|spectrometer is used for quantitative and qualitative elemental analysis of metal alloys, liquids, food and biological samples, powder assays, as well as samples deposited on surfaces or filters, in the element range from Cl (Z=17) to U (Z=92) in a wide range of element concentrations. The accuracy of determining concentrations is better than 0.3% for metal alloys. XRF analyzers detecting limit is better than 1 ppm for most elements in light matrix.

   The EDXRF spectrometer|analyzer is registered in the State registry of measurement instruments accepted for usage in Ukraine under the number У1411‑01. Certificate of the measurement instrument type is UA‑MI/1‑971‑2001.

Fields of application

  • RoHS & WEEE
  • Jewelry
  • Metallurgy
  • Medical diagnosis
  • Ecological monitoring
  • Customs and criminalistic expertise
  • Archaeological studies
  • Chemical industry
  • Oil-refining industry
  • Geology and mineralogy
  • Food industry
  • Scientific research 

    XRF analyzer "ElvaX" - is used for metal analyzing - for quantitative and qualitative analysis of the elemental composition of metal alloys, liquids, food and biological samples...

Basic user specifications of EDXRF Spectrometer (analyzer)

Element detection range from Cl (Z=17) to U (Z=92)
Data acquisition time 10 – 1200 s
Power supply 90 - 240 V, 50/60 Hz
Power consumption 40 W
Dimensions 430 mm x 340 mm x 200 mm
Weight 18 kg

Technical characteristics

X-ray source

X-ray tube W or Ag anode
250 µm Be window
air-cooling
X-ray generator voltage: 4–50 kV, adjustable in 100 V steps
current: 0–100 µA, adjustable in 0.2 µA steps
maximal power: 5 W
Stability 0.1% per 8 hours

X-ray detector

Detector type solid state Si-pin-diode with thermo-electrical cooling
Active area 6 mm2
Energy resolution 165 eV at 5.9 keV (Fe55 isotope)
Be window thickness 25 µm

Spectrometric processor

Pulse processor digital pulse processor
pile-up rejection
pulse shape selector
automatic adjustment to count rate
ADC 4096 channels
Buffer RAM 4096 32-bit channels
Timers real and "live" time

Software

Supported operating systems Windows XP/Vista/7
Quantitative analysis algorithms fundamental parameters
quadratic stepwise multiple regression
manual spectra comparison

Options

Built-in CCD Camera 1.3 Mpixel
Autosampler 8 positions, 32 mm diameter